The purpose of this study was to examine perio dressing adhesion of 3 different materials.
Coe-Pak, Peripac and Peripac Improved. Policarboxylate cement was used as control.
Materials were placed over enamel and examined 1 hr, 1 day, 1 week later.Coe-Pak showed the higher value of adhesion. All materials were far below control adhesion